3
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
OUTLINE OF THE MACHINE
3 - 41
3.10 Drive System
3.10.1
General Description
The main motor (M3) drives the drum, developer unit, cleaner unit, fuser unit and transport rollers which
transport paper (bypass feed roller, registration roller and paper feed roller).
The main motor (M3) is a brushless motor and is installed in the drive unit. The drive unit consists of
gears and clutch, and transmits the driving force of the main motor (M3) to each unit. The toner motor
(M2) which drives the toner cartridge is also installed in the drive unit.
The exit roller is driven by the main motor (M3). However, when the automatic duplexing unit (ADU:
optional) is installed, it is driven by the exit motor (M6).
Fig. 3-42
[1] Main motor (M3)
[2] For mixer
[3] Toner motor (M2)
[4] Drive unit
[5] For fuser roller
[6] For toner cartridge auger
[7] For drum
[8] For bypass feed roller
[9] For paper feed roller
[10] Exit motor (M6)
[11] Exit roller
[1]
[3]
[4]
[5]
[2]
[6]
[7]
[8]
[9]
[10]
[11]
[11]
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...