![Toshiba E-STUDIO2006 Скачать руководство пользователя страница 678](http://html.mh-extra.com/html/toshiba/e-studio2006/e-studio2006_service-manual_424141678.webp)
05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
23LA
23LM/
28LM
23HA/
28HA
08
Setting
mode
Process
Fuser
5497
3
Low power
consumption control:
Lamp maximum ON
time (Side)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
4
Low power
consumption control:
Lamp maximum ON
time (Center)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
5
Low power
consumption control:
Lamp maximum ON
time (Side)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
6
Low power
consumption control:
Lamp maximum ON
time (Center)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5497
7
Low power
consumption control:
Lamp maximum ON
time (Side)
10
1-50
M
This code is used to set a Lamp ON time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5498
0
Low power
consumption control:
Lamp maximum OFF
time (Center)
22
1-50
M
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5498
1
Low power
consumption control:
Lamp maximum OFF
time (Side)
22
1-50
M
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5498
2
Low power
consumption control:
Lamp maximum OFF
time (Center)
20
1-50
M
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
08
Setting
mode
Process
Fuser
5498
3
Low power
consumption control:
Lamp maximum OFF
time (Side)
20
1-50
M
This code is used to set a Lamp OFF time on Low power
consumption control. Use the above default value, unless
otherwise required.
Setting value x 100 msec
4
Y
Y
Y
e-STUDIO2303A/2303AM/2803AM/2309A/2809A
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-2-62
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved