05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Process
Fuser
Fuser roller
temperature during
printing (Side
thermistor)
2142
-
Thick paper 2
11
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C 13: 205 degrees C 14: 210
degrees C
1
Y
Y
08
Setting
mode
Process
Fuser
Fuser roller
temperature during
printing (Side
thermistor)
2143
-
OHP film
8
0-14
M
0: 140 degrees C 1: 145 degrees C 2: 150 degrees C
3: 155 degrees C 4: 160 degrees C 5: 165 degrees C
6: 170 degrees C 7: 175 degrees C 8: 180 degrees C
9: 185 degrees C 10: 190 degrees C 11: 195 degrees
C 12: 200 degrees C 13: 205 degrees C 14: 210
degrees C
1
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
2190
0
The first drop
1
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
2190
1
The second drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
2190
2
The third drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Center
thermistor)
2190
3
The fourth drop
3
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
2191
0
The first drop
2
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
2191
1
The second drop
3
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
2191
2
The third drop
4
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y
08
Setting
mode
Process
Fuser
Temperature drop
setting during
printing (Side
thermistor)
2191
3
The fourth drop
5
0-10
M
Setting value x -5 degrees C: from 0 degrees C to -50
degrees C
4
Y
Y