e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 26
6.4.5
Gamma balance adjustment
The density is adjusted by adjusting the gamma balance. The adjustment is performed by selecting its
density area from the following: low density, medium density and high density.
< Adjustment Mode (05) >
Notes:
Changing the adjustment setting influences the adjacent density area slightly.
E.g.: When the value of the medium density is larger, the adjacent areas in the low density and
high density range will become slightly darker.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in the code for an item to be adjusted and then press the [START] button.
(3) Key in a number for the density area to be adjusted (0, 1 or 2), and then press the [START]
button.
0: Low density 1: Medium density 2: High density
(4) Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR/STOP] button.)
(5) Press the [OK] button to store the value in memory. The equipment goes back to the test mode A
screen.
(6) For resetting the value, repeat step (2) to (5).
(7) Press the [SETTINGS] button and then the [START] button. Then perform test copying.
(8) If the desired image density has not been attained, repeat step (2) to (7).
Language and screen
BackGround
Erase
Item to be
adjusted
Remarks
Text/Photo
Photo
Text
7190-0
7192-0
7191-0
7195-0
Low density
The larger the value is, the density of
the item to be adjusted becomes darker.
Acceptable values: 0 to 255.
(Default: 128)
7190-1
7192-1
7191-1
7195-1
Medium
density
7190-2
7192-2
7191-2
7195-2
High density