e-STUDIO2006/2306/2506/2007/2307/2507/2303A/2303AM/2803AM/2309A/2809A
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 72
8.4.6
Poor fusing
Fig.8-8
Defective area
Step
Check items
Prescription
Heater electric power
1
Check if the connector contacts
properly.
Correct it.
2
Is the heater shorted or broken?
Replace the heater.
Pressure between fuser
roller and pressure roller
3
Are the pressure springs working
properly?
Check and adjust the pressure
springs.
Fuser roller temperature
4
Is the temperature of the fuser roller
normal?
Check the setting and correct it.
08-2010, 2009, 2100
Developer material/Toner
5
Using the specified developer
material and toner?
Use the specified developer material
and toner.
Paper
6
Is the paper in the drawer damp?
Avoid storing paper in damp place.
7
Is the paper type corresponding to its
mode?
Use the proper type of paper or
select the proper mode.
8
Is the setting temperature of the fuser
roller in each paper type normal?
Check the setting and correct it.
(08-2049, 2050, 2051, 2194)
9
Using the recommended paper?
Use the recommended paper.
Feeding direction