[C] Reproduction ratio adjustment of the secondary scanning direction
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(Adjustment Mode)
(2) Place a ruler on the original glass with its leading edge pushed against the original scale on the
left.
(3) [SETTINGS]
[USER FUNCTIONS]
Select [DRAWER]
Select [DRAWER1]
Set the paper size to A3/LD.
[OK]
Set A3/LD for the paper in upper drawer.
(4) [CANCEL]
[CANCEL]
Select the upper drawer by pressing [DRAWER].
Press [START]
to make copies.
(5) Measure the distance C from 200 mm to 400 mm of the copied image of the ruler.
(6) Check if the distance C is within the range of 200±0.5 mm.
(7) If not, use the following procedure to change values and measure the distance C again.
[SETTINGS]
(Key in the code [3032])
[START]
(Key in a value (acceptable values: 0 to 255))
[OK] (Stored in memory)
[SETTINGS]
Select the upper drawer by pressing [DRAWER].
Press [START] to make
copies.
* The smaller the adjustment value is, the lower the reproduction ratio becomes (approx. 0.06
mm/step).
Fig.6-11
200
250
300
350
400
50
100
150
C
Feeding direction
Copied image of the ruler