![Toshiba E-STUDIO2006 Скачать руководство пользователя страница 600](http://html.mh-extra.com/html/toshiba/e-studio2006/e-studio2006_service-manual_424141600.webp)
05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
Counter
Process
Toner cartridge
usage history (Lot.
No.)
6977
4
4 cartridge earlier
0
0-99999999
M
1 digit: Production location indicated.
-0: Cartridge not installed
-1: TESS cartridge
-2: TABS cartridge
-3: TEIS cartridge
-6: Cartridge not detected (when the IC chip information
cannot be detected)
8 digits: Lot No. indicated
4
Y
Y
08
Setting
mode
Image
Processiing
Image
Clearing of
adjustment values
of all image process
(PPC) related 05
codes
7000
-
PPC
-
-
SYS/
M
clear
Clears the adjustment values of the following 05 codes: 05-
7000 to 7299, 7600 to 7999 After executing this code.
3
Y
Y
08
Setting
mode
Image
Processiing
Image
Clearing of all
gamma
correction table
values (PPC related
areas only)
7001
-
PPC
-
-
SYS
clear
Clears all the gamma correction table values in the PPC
related areas of the memory.
3
Y
Y
08
Setting
mode
Image
Processiing
Image
Error diffusion and
dither setting
7014
-
Photo mode
1
0-1
SYS Sets the image reproduction method at photo mode.
0: Error diffusion 1: Dither
1
Y
Y
08
Setting
mode
Image
Processiing
Image
Last updated date
and time
7051
-
PPC
0
0-
4212312359
SYS Last updated date and time of automatic tone correction
data. (YYYYMMDDHHMM)
YYYY: Year, MM: Month, DD: Date,HH: Hour: MM: Minute
2
Y
Y
08
Setting
mode
Image
Processiing
Image
Clearing of
adjustment values
of all image process
(Network printer)
related 05 codes
7300
-
PRT
-
-
SYS
clear
M
clear
Clears the adjustment values of the following 05 codes: 05-
7300 to 7399, 05-8200 to 8299 After executing this code.
3
Y
Y
08
Setting
mode
Image
Processiing
Image
Clearing of
adjustment values
of all image process
(network scan)
related 05 codes
7400
-
SCN
-
-
SYS
clear
Clears the adjustment values of the following 05 codes: 05-
7400 to 7499, 05-8300 to 8499 After executing this code.
3
Y
Y
08
Setting
mode
Image
Processiing
Image
Clearing of
adjustment values
of all image process
(Fax) related 05
codes
7500
FAX
-
-
SYS
clear
Clears the adjustment values of the following 05 codes: 05-
7500 to 7599 After executing this code.
3
-
Y
08
Setting
mode
System
User
interface
Screen setting
8523
-
Toner near-empty
status Message
1
0-1
SYS 0: ON
1: OFF
1
Y
Y
08
Setting
mode
System
User
interface
Counter
8549
-
Hardware key control
when external counter
is installed
0
0-1
SYS 0: No control
1: Mode switch key is disabled.
1
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-1-80
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved