Adjustment Mode (05) Codes
05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptabl
e value
SRAM
Contents
Proce
dure
20L /
23L /
25L
20H /
23H /
25H
05
Adjustment
mode
Process
Developm
ent
2000
-
Auto toner sensor auto
adjustment (heater ON)
-
-
-
As the value increases, the sensor output increases
correspondingly.
17
Y
Y
05
Adjustment
mode
Process
Developm
ent
2001
-
Auto toner sensor
manual adjustment
(heater ON)
165
0-255
M
Corrects the control value of the auto-toner sensor setup in
05-2000.
* Selection is disable when developer unit is not installed.
3
Y
Y
05
Adjustment
mode
Process
Developm
ent
2020
-
Developer bias DC
output adjustment
131
0-255
M
As the value increases, the transformer output increases
correspondingly.
3
Y
Y
05
Adjustment
mode
Process
Charger
2040
-
Main charger grid bias
output adjustment
123
0-255
M
As the value increases, the transformer output increases
correspondingly.
3
Y
Y
05
Adjustment
mode
Process
Transfer
2052
-
Transfer transformer
DC output adjustment
(Center)
138
78-255
M
As the value increases, the transformer output increases
correspondingly. (Main motor, main charger, discharge
LED, transfer ON)
3
Y
Y
05
Adjustment
mode
Process
Separation
2078
-
Separation transformer
DC output adjustment
(Center)
52
0-255
M
As the value increases, the transformer output increases
correspondingly. (Main motor, discharge LED, separation
DC / separation AC ON)
3
Y
Y
05
Adjustment
mode
Process
Transfer
2083
-
Transfer cleaning bias
adjustment (Positive)
118
78-255
M
The larger the setting value is, the higher the value of the
current (more positive) is.
3
Y
Y
05
Adjustment
mode
Process
Transfer
2084
-
Transfer cleaning bias
adjustment (Negative)
66
0-77
M
The larger the setting value is, the higher the value of the
current (more negative) is.
3
Y
Y
05
Adjustment
mode
Process
Image
control
2192
-
Relative humidity latest
value
50
0-100
M
Displays the humidity value detected by
temperature/humidity sensor.
2
Y
Y
05
Adjustment
mode
Process
Image
control
2194
-
Temperature latest
value
25
0-50
M
Displays the temperature value detected by
temperature/humidity sensor.
2
Y
Y
05
Adjustment
mode
Process
Image
control
2196
-
Drum temperature
latest value
25
0-100
M
(Unit: degrees C)
2
Y
Y
05
Adjustment
mode
Process
Image
control
2250
-
Laser power
adjustment
118
0-255
M
When the value increases, the laser output increases
correspondingly.
3
Y
Y
05
Adjustment
mode
Process
Image
control
2382
-
Reverse time of the
drum
13
0-255
M
1
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved