05/08
Mode
Element
Sub element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
SRAM
Contents
Proce
dure
20L/
23L/
25L
20H/
23H/
25H
08
Setting
mode
System
9060
-
Destination display at
flash memory
initialization
Refer to
contents
0-12
SYS 20 ppm: 0: MJD, 1: NAD, 3: AUD, 9: ASD, 10: ARD, 12:
FJP
23 ppm: 1: NAD, 3: AUD, 4: CND, 9: ASD
25 ppm: 0: MJD, 1: NAD, 4: CND, 9: ASD, 10: ARD
When selecting 12: FJP do the same initialization as 2: JPD
<Default value>
MJD: 0, NAD: 1, AUD: 3, CND: 4, TWD: 6, SYD: 11ASD: 9,
ARD: 10, JPD: 12
2
Y
Y
08
Setting
mode
System
General
9063
-
Presence of the fax
board
0
0-1
SYS 0: The fax board is not attached
1: The fax board is attached
1
-
Y
08
Setting
mode
System
General
9081
-
Initialization of
department
management
information
-
-
SYS Initializing of the department management information.
3
Y
Y
08
Setting
mode
System
Initialization
9083
-
Initialization of NIC
information
-
-
SYS Returns the value to the factory shipping default value.
3
-
Y
08
Setting
mode
System
All clear
9090
-
Printer all clear
-
-
M
Initializes all the self-diagnosis 05/08 codes with "M" in the
"RAM" field.
3
Y
Y
08
Setting
mode
System
General
9100
Date and time setting
-
-
-
YYMMDD Day of the week HHMMSS
(Year/month/date/day/hour/minute/second)
Example:
03 07 01 3 13 27 48
"Day" - "0" is for "Sunday". Proceeds Monday through
Saturday from "1" to "6".
11
Y
Y
08
Setting
mode
System
User
interface
9102
Date format
2
0-2
SYS 0: YYYY.MM.DD
1: DD.MM.YYYY
2: MM.DD.YYYY
<Default value>
MJD: 1
JPD: 0
Others: 2
1
Y
Y
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
14-1-86
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...