08
Setting
mode
Counter
PM counter
Fuser separation
finger
6368
4
Recommended driving
counts to be replaced
345000
0-345000
M
4
Y
Y
08
Setting
mode
Counter
PM counter
Fuser separation
finger
6368
5
Driving counts at the
last replacement
0
0-345000
M
4
Y
Y
08
Setting
mode
Counter
PM counter
Fuser separation
finger
6368
6
Present output pages
for control
0
0-600000
M
4
Y
Y
08
Setting
mode
Counter
PM counter
Fuser separation
finger
6368
7
Present driving counts
for control
0
0-345000
M
4
Y
Y
08
Setting
mode
Counter
PM counter
Fuser separation
finger
6368
8
Number of times
replaced
0
0-600000
M
4
Y
Y
08
Setting
mode
Counter
PM counter
Fuser separation
finger
6369
-
Date of previous
replacement
29991231
-
M
(YYYYMMDD)YYYY: Year, MM: Month, DD: Date (Max. 8
characters)
2
Y
Y
08
Setting
mode
Counter
PM counter
Pickup roller
(RADF)
6382
0
Present number of
output pages
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Pickup roller
(RADF)
6382
1
Recommended number
of output pages for
replacement
150000
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Pickup roller
(RADF)
6382
2
Number of output
pages at the last
replacement
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Pickup roller
(RADF)
6382
8
Number of times
replaced
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Pickup roller
(RADF)
6383
-
Date of previous
replacement
0
-
SYS (YYYYMMDD)YYYY: Year, MM: Month, DD: Date (Max. 8
characters)
2
Y
Y
08
Setting
mode
Counter
PM counter
Feed roller (RADF)
6384
0
Present number of
output pages
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Feed roller (RADF)
6384
1
Recommended number
of output pages for
replacement
150000
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Feed roller (RADF)
6384
2
Number of output
pages at the last
replacement
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Feed roller (RADF)
6384
8
Number of times
replaced
0
0-99999999
SYS
4
Y
Y
08
Setting
mode
Counter
PM counter
Feed roller (RADF)
6385
-
Date of previous
replacement
0
-
SYS (YYYYMMDD)YYYY: Year, MM: Month, DD: Date (Max. 8
characters)
2
Y
Y
© 2013-2017 TOSHIBA TEC CORPORATION All rights reserved
14-1-73
e-STUDIO2006/2306/2506/2007/2307/2507
SELF-DIAGNOSIS CODE (03/04/05/08 CODE)
Содержание E-STUDIO2006
Страница 14: ......
Страница 729: ......
Страница 730: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...