SETTING / ADJUSTMENT
6 - 5
[Procedure to key in adjustment values]
In accordance with the procedure described below, make adjustment of each adjustment item so that
the measured values obtained from test copies satisfy the specification. By pressing the [SETTUNGS]
button, immediately after starting the Adjustment Mode (05), single-sided test copying can be
performed (normal copy mode).
Fig.6-6
6.3.2
Light volume adjustment of scanner LED
Perform the light volume adjustment of scanner LED according to the following procedure.
<Procedure>
(1) While pressing [0] and [5] simultaneously, turn the power ON.
(2) Key in a code “3219” and press the [START] button. The automatic adjustment starts. When the
adjustment is completed, “COMPLETED” appears.
0
5
POWER
OK
Digital keys
START
: Enter codes.
<Operation keys>
<Display>
Power OFF/ON : Exit the Adjustment Mode.
Test copy
Digital keys : Enter adjustment
values.
Value 128 is stored
replacing values 130.
If the test copy does not
satisfy the specified values,
return to step and
repeat the adjustment
procedure.
( CLEAR/STOP Use to make corrections)
CLEAR/STOP
1
SETTINGS
START
TEST MODE A
MC=
TEST MODE A
MC=
TEST MODE A
MC=
4000
TEST MODE A
MC=4000
128
TEST MODE A
MC=4000
130
TEST MODE A
MC=4000
Test
AUTO EXPOSURE
TEXT
100 %
A4
1
1
1
Default value
Code No.