Chapter 3
SYSTEM SETTINGS (NX-300 SETTING SOFTWARE)
3- 1
13. CONTROL OUTPUT SETTINGS
Step 1.
Select the units to be set from the unit list in the setup editing screen.
Step 2.
Select the "Control I/O" tab and click the Control output button.
The control output setting screen is displayed.
Step 3.
Set each item.
1. Control output No.
Click the control output number to be set.
Selectable in the range of 1 10 for the NX-300 units and 1 for the NX-100 and NX-100S units.
2. Enable
Set to be checked by default.
When the control output is not used, uncheck the checkbox to invalidate the control output settings.
3. Mode
Select the operation mode. Contents differ depending on the unit being set.
• For the NX-300 units
Standard:
Standard operation mode. Control output is activated by the PC or contact bridge
control of an operated unit or other unit.
Broadcasting:
Control output is activated during a broadcast.
O T1-broadcasting
When audio is provided from Audio Output 1, the control output is activated.
O T -broadcasting
When audio is provided from Audio Output 2, the control output is activated.
Error:
Control output is activated while the error indicator lights.
Click