(2) V/F Curve Selection (Sn-02)
• V/F curve is selected by the setting of Sn-02. When V/F curve is selected, always set input
voltage of the AC drive to Cn-01.
• Sn-02= 0~3: pre-set V/F curve pattern.
Sn-02= 4: V/F pattern is set by the user (see parameters Cn-02~Cn-08).
Table 12: V/F curve of 230V class
Sn-02 Setting
Specifications
V/F Pattern
0
50Hz, Saturation Variable Torque
(quadratic monotonically
decreasing curve)
1
50Hz, Saturation Variable Torque
(cubic monotonically decreasing curve)
2
60Hz, Saturation Variable Torque
(quadratic monotonically
decreasing curve)
3
60Hz, Saturation Variable Torque
(cubic monotonically decreasing curve)
*1. Consider the following items as the conditions for selecting a V/F pattern.
They must be suitable for:
1. The voltage and frequency characteristic of the motor.
2 The maximum speed of the motor.
*2. For 460V class, 2 times voltage value shown in table above.
2-32
PA 7300
PART II: OPERATION MANUAL
1.3 25 50 (Hz)
(V)
55
38
10
8
0
1
1.5 30 60 (Hz)
(V)
230*2
230*2
55
38
9
8
2
3
Содержание PA7300 Series
Страница 9: ......
Страница 10: ...PART I INSTALLATION MANUAL ...
Страница 44: ...PART II OPERATION MANUAL ...
Страница 107: ...2 57 PA 7300 PART II OPERATION MANUAL REDUCTION COEFFICIENT ...
Страница 116: ...2 66 PA 7300 PART II OPERATION MANUAL 2 5 Monitoring Peramiters UN ...
Страница 117: ...2 67 PA 7300 PART II OPERATION MANUAL ...
Страница 150: ...i PA 7300 INSTRUCTION MANUAL ...
Страница 151: ...i PA 7300 INSTRUCTION MANUAL ...
Страница 152: ...i PA 7300 INSTRUCTION MANUAL ...
Страница 153: ...i PA 7300 INSTRUCTION MANUAL ...
Страница 154: ...5100 N IH 35 Round Rock Texas 78681 USA 1 800 279 4007 www tecowestinghouse com ...