![TECO-Westinghouse FLUXMASTER 100 Series Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/teco-westinghouse/fluxmaster-100-series/fluxmaster-100-series_maintenance-and-operation-manual_1072543053.webp)
51
Fn_102
:
Communication Parameters
xxx0:
1 Stop Bit
xx0x: Even
Parity
x0xx: Without
Parity
0xxx:
8 Bits Data
xxx1:
2 Stop Bits
xx1x:
Odd Parity
x1xx:
With Parity
1xxx:
7 Bits Data
Note:
To use RS-485, the optional RS-485 Interface Card is required.
a.
For one to one control: Using a PC, PLC or some sort of control device to control one drive,
set (
Fn_100
) to (1).
b. When controlling multiple Inverters using a PC, PLC or some sort of control device to control
multiple Inverters, set up (
Fn_100
) according to the number of Inverters you are controlling.
Each number will identify and be used as the address for the Inverters identification and
parameter setup change.
c.
Up to 32 Inverters can be controlled simultaneously using the communication interface
function.
d. If the PC sends the code 33 to the Inverters, all linked Inverters (up to 32) can be controlled
simultaneously. All receiving the same signal or parameter change.