13
Function Description for the Main Circuit Power Terminals (TM1)
SYMBOL
FUNCTION DESCRIPTION
L1 (R)
Input Terminals of AC Line Power: 230 or 460 Volt
L2 (S)
Single Phase: L1 / L2
L3 (T)
Three Phases: L1 / L2 / L3
P
R
External Braking Resistor Terminals
T1 (U)
T2 (V)
T3 (W)
Output Terminals to Motor
Function Description for the Control Terminals (TM2)
SYMBOL
FUNCTION DESCRIPTION
1
Fault Relay Output Terminals: (
Fn_97, 98
)
2
TRIP
RELAY
Contact Rating: 250VAC / 1A (30VDC / 1A)
3
FWD
4
REV
Operation Control Terminals (
Fn_03
)
5
COM
Ground Common for Terminals 3 / 4 / 6 / 7 / 8 / 9
6
SP1
7
SP2
8
SP3
Multi-Function Input Terminals (
Fn_56
)
9
RESET
Reset Terminal (
Fn_16
)
10
SYN-
Negative Terminal for Multi-Function Output (
Fn_61
)
11
SYN+
Positive Terminal for Multi-Function Output (
Fn_61
)
12
+
+5V Power Terminal of Potentiometer (
Pin 3
)
13
Analog Analog Freq. Signal Input Terminal (
Fn_26
)
Input Positive Terminal
0 - 5VDC, 0 - 10VDC, 4 - 20mA
14
_
FM -
Analog Common Terminal for Analog Frequency
Common Negative Terminal
0 - 5VDC, 0 - 10VDC, 4 - 20mA
15
FM +
Analog Multi-Function Output Terminal (
Fn_46
)
Output (+) Range of Output Signal: 0 - 10VDC