![TECO-Westinghouse FLUXMASTER 100 Series Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/teco-westinghouse/fluxmaster-100-series/fluxmaster-100-series_maintenance-and-operation-manual_1072543017.webp)
15
Parameter List
Function
Fn_
xx
Description
Engineering
Units
Range
Factory
Setting
Page
Drive Capacity
0
Drive Capacity Selection
1
1 - 18
*3
23
Accel Time
1
Accel Time 1
0.1 sec
0.1 - 3600
sec
10 sec
23
Decel Time
2
Decel Time 1
0.1 sec
0.1 - 3600
sec
10 sec
23
Stop / Start
Control
TM2
3
xx00 : FWD / STOP, REV / STOP
xx01 : FWD / REV, RUN / STOP
xx10 : 3-Wire Start / Stop Control
x0xx : REV Command Enable
x1xx : REV Command Disable
0xxx : Setting Frequency will remain at last Output Frequency
when
Inverter stops and
Fn_11
= 3
1xxx : Setting Frequency will be 0 (zero) when Inverter stops
and
Fn_11
= 3
0000
24
Parameter
Lockout
4
xxx0 : Enable (
Fn_17 - 25
)
xxx1 : Disable (
Fn_17 - 25
)
xx0x : Enable (Functions except
Fn_17 - 25
)
xx1x : Disable (Functions except Fn_17 - 25)
0000
25
V/Hz Pattern
5
V/Hz Pattern Selection
1
0 - 18
9 / 0
25
6
Frequency Upper Limit
0.01Hz
0 - 400Hz
60 / 50
27
Frequency
Limit
7
Frequency Lower Limit
0.01Hz
0 - 400Hz
0Hz
27
Target Speed
8
Target Frequency Setting
0.01Hz
0 - 400Hz
0Hz
27
Target Speed
Bandwith
9
Frequency Setting Detection
Width (+ / - F9 / 2)
0.01Hz
0 - 30Hz
0Hz
27
START / STOP
Selection
10
0 : Keypad
1 :
TM2
0
28
Frequency
Command
Selection
11
0 : Controlled by (
Fn_25
) Master Reference at Keypad
1 : Controlled by Keypad Frequency Setting Potentiometer
2 : Controlled by
TM2
(Speed Pot)
3 : Controlled by Preset Speeds or Multi-Function Inputs
(Terminals 6 / 7 / 8)
0
28