25
Fn_04: Parameter Lockout
Parameter Lock Select
xxx0 Disable (
Fn_17-25
)
xx01: Enable (
Fn_17-25
)
xx0x: Disable (Functions except
Fn_17-25
)
xx1x: Enable (Functions except
Fn_17-25
)
Fn_05:
V/Hz
Pattern Setting / Custom or Preprogrammed
V/F Pattern Selection
= 0 - 18 (See Page 24)
Fn_30
: Voltage of Input Power Supply = 200 - 480 Volts
Fn_37
: Maximum Frequency
= 50 - 400Hz
Fn_38
: Maximum Voltage Ratio
= 0 - 100%
Fn_39
: Middle Frequency
= 0.11 - 400Hz
Fn_40
: Middle Voltage Ratio
= 0 - 100%
Fn_41
: Voltage Ratio at 0.1Hz
= 0 - 100%
Fn_48
: AVR Control
= 0xxx, AVR Function effective
= 1xxx, AVR Function ineffective
In order to build Custom V/Hz Patterns, (
Fn_05
) must be set at 18.
Please refer to (
Fn_37
) and (
Fn_41
).
(V)
Fn_38
(Vmax)
Fn_40
(Vmid)
Fn_41
(Vmin)
Hz
0.1
Fn_39
Fn_37
400