44
Fn_71
:
Torque Boost
x0xx:
Torque Boost enable
x1xx:
Torque Boost disable
1xxx:
Manual Torque Boost
Fn_72
:
Torque Boost Gain:
0.0 to 10.0%
Note:
In (
Fn_71
), when using the setting (x1xx), both Auto and Manual Torque Boost are inactive.
When using the setting (0xxx), the Inverter adjusts the Torque Boost by automatically
adjusting to the Inverters output current.
When using the setting (1xxx), the Torque Boost is adjusted according to the settings
in V/F pattern (
Fn_05
) and (
Fn_72
).
Fn_75
:
Motor No Load Current
_ _ _ _ _
Fn_76
:
Motor Rated Slip:
0.0 - 6.00Hz
Fn_77
:
Overtorque Control
xxx0:
Overtorque Detection disable
xxx1:
Overtorque Detection enable
xx0x:
Enable only if at Set Frequency
xx1x:
Enable during Operation
x0xx:
Operation continued after Overtorque is detected
x1xx:
Coast to Stop after Overtorque is detected