12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
93
Provisioning and Operating the SSU-2000
Initial Provisioning
1. Connect a computer to the SSU-2000 using the procedure in
SSU-2000>
prompt appears.
2. Log in to the SSU-2000:
ICS command:
Type
login
followed by the administrator’s user name and press
Enter
. The
system prompts for a password. Type the administrator’s password and press
Enter
. The system prompt
SSU-2000>
appears.
TL1 command:
Type
ACT-USER::uid:123::pwd;
where
uid
and
pwd
are the administrator’s user id and password, respectively;
123 is an arbitrary ctag value.
3. Provision the reference selection mode. Priority is the default reference selection
mode, and the most widely used mode. See
information on selecting the appropriate mode.
ICS command:
Type
REF MODE PRI
then press
Enter
.
TL1 command:
Type
SET-INPUT-REF:::123::port,PRI;
where 123 is an arbitrary ctag value and port is the selected input port in the
format S1Ax[-z], where x is the slot number (3–12) and z is the channel number
(1–3).
Repeat this command for all inputs.
4. Provision the clocks to enable auto-return (revertive) mode. Symmetricom
generally recommends that auto-return be set to On, unless both clocks are of
the same Stratum level. See
Setting the Reference Switching Mode
for more information on revertive and non-revertive modes.
ICS command:
Type
CLK AR ON
then press
Enter
.
TL1 command:
SET-CLK-AR:::123::ON;
5. Provision the IP, Gateway, and Subnet addresses for the SSU-2000. The IT
department or site administrator for your location can recommend specific
addresses for these parameters. Use the format xxx.xxx.xxx.xxx for the address.
ICS commands:
Type
IP ADDR [ip address]
then press
Enter
.
Type
IP GATEWAY [gate address]
then press
Enter
.
Type
IP SUBNET [subnet address]
then press
Enter
.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...