TL1 Command Interface
306
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
SET-PRMTR-ALARM:[tid]:aid:
ctag::almnum,level
[,errcnt],[clrcnt];
Valid aid code:
ALL
,
SxAy
This command assigns an alarm level to the alarm number
specified.
almnum
= alarm number. See
242 for a list of alarm numbers.
level
= [IGN|RPT|MIN|MAJ|CRT]
start delay time or erred seconds count
errcnt
and clear delay time for the indicated alarm
number
clrcnt
on the modules specified by the aid.
SET-PRMTR-AIS:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-BPV:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-CRC:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-LOS:tid:[aid]:ctag
::[errcnt],[clrcnt];
SET-PRMTR-OOF:tid:[aid]:ctag
::[errcnt],[clrcnt];
Valid aid code:
ALL
,
SxAy-[z]
This command sets the input error and clear parameters of
[AIS|BPV|CRC|LOS|OOF] for the designated input.
errcnt
and
clrcnt
= number of seconds to delay
[0|...|100] before reporting the condition for LOS and AIS
input errors
errcnt
and
clrcnt
= number of seconds to delay
[0|...|100000] before reporting the condition for OOF, BPV,
and CRC input errors
When aid is set to ALL, the specified parameters are set for
all inputs.
SET-PRMTR-CCOUT:[tid]:[aid]:
ctag::[pstate],[mode],
[level],[bypass],[duty],
[pcomp];
Valid aid code:
ALL
,
SxA[y[-z]]
pstate
sets the output port [ON|OFF]
mode
= ignored
level
= the condition where outputs are turned on
[WARM |ACQ|LOCK]
bypass
= allow Clock C selection: [ON|OFF]
duty
= set duty cycle to use 5/8 or 50/50 [1|0]
pcomp
= set phase compensation delay to [0 through 8],
where 0 = No compensation and 8 = 4000 ft. The
resolution of pcomp values is 500 ft. Setting the status for
a module (no port
–z
) sets all ports on the module to
[ON|OFF]
Empty fields leave parameters unchanged.
SET-PRMTR-CLK:[tid]:[aid]:
ctag::[warmup],[mintau],
[maxtau];
Valid aid code:
S1A1
,
S1A12
,
CLK-A
,
CLK-B
This command sets the designated clock warmup time.
warmup
= warmup time constant; set to 1200 seconds
mintau
= starting time constant
maxtau
= final time constant value
ST2E tau range = [300–10000]
ST3E tau range = [150–1200]
The aid may be specified to indicate which clock; set to null to
set both clocks identically.
Empty fields leave parameters unchanged.
Table B-6. TL1 Set Commands (Continued)
Command
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...