Interactive Command Set
356
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
OUTPUT
Use this command to view or set the output module status.
Level 0
Not applicable
Level 1
OUTPUT [xAy]
If you do not provide a parameter, all the output module status
information in the unit displays. If you provide an output address,
the output status and setup information for that output module
displays.
Status Information: Output module status, selected clock, all four
clock statuses, redundant partner, output PQL value, and output
port status
Setup Information: Framer type, zero suppression (On or Off),
minimum clock level, PLL mask (On or Off)
If DS1: line length
If E1: CRC (On or Off), SSM bit position (4-8)
The alarm level is handled by the ALARM command. The alarm
elevation time is handled by ELEVTIME command.
Example:
SSU_2000->output
2001-05-24T18:29:00Z ID: SSU2000 Name: SSU_2000
OUT STA Clk Clk Stat Port Status 1 1 1 1 1 1 1 1 1 1 2
Loc# Sta Sel A B C D Rednt M/S Pql 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- --- --- -------- ----- --- --- --------------------------------------
2A01 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A02 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A03 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A04 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A05 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A11 Ok A /Y/Y/Y/Y 3A12 (S) 2 / / / / / / / / / / / / / / / / / / / /
3A12 Ok A /Y/Y/Y/Y 3A11 (M) 2 / / / / / / / / / / / / / / / / / / / /
1A06 Ok A /Y/Y/Y/N 1A07 (M) NA / / / / / / / / / / / / / / / / / / / /
1A07 Ok A /Y/Y/Y/N 1A06 (S) NA / / / / / / / / / / / / / / / / / / / /
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
OUTPUT xAy {ESF|D4|CCS|CAS}
OUTPUT xAy-z[&&z] {E1|2048}
OUTPUT xAy-z[&&z] {ENABLE|DISABLE}
OUTPUT xAy LEVEL {ACQ|LOCK}
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...