Provisioning and Operating the SSU-2000
Initial Provisioning
94
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
TL1 command:
SET-PRMTR-IP:::123::[ip address],[gate address],[subnet address];
6. Assign a name, if desired, to the SSU-2000. You can assign a
[name]
of up to 20
characters, starting with a letter; the name is returned as the
tid
in responses
from the unit.
ICS command:
Type
NAME
, [name] then press
Enter
.
TL1 command:
SET-NAME:S1A2::123::[name];
You can also use this command to assign a name to inputs and outputs.
Provisioning GPS Input Modules
This section describes how to enable GPS Input modules, if they are installed. You
must assign a priority level to each module. You can install GPS Input modules only
in slot 3 and slot 5 of the main SSU-2000 shelf.
Set the priority level for each module.
ICS command:
Type
INPUT 1A3 PRI 1
then press
Enter
.
Type
INPUT 1A5 PRI 1
then press
Enter
, if a module is present in slot 5.
TL1 command:
SET-PRMTR-INPUT::S1A3:123::ON,1;
enables the module in slot 3 and sets its Priority to 1.
SET-PRMTR-INPUT::S1A5:123::ON,1;
enables the module in slot 5 and sets its Priority to 1.
Provisioning Other Input Modules
This section describes how to enable and provision other types of Input modules
such as DS1, E1, or Composite Clock. You must enable and provision each input
port as appropriate for the input signal. You can install these Input modules in any
slot in the main SSU-2000 shelf.
1. Enable the modules.
ICS command:
Type
INPUT xAy ENABLE
then press
Enter
where x is the slot number and y is the port number. Repeat this command for
each port and each slot.
TL1 command:
See the command in step 2, below.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...