Event Messages
254
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Event Messages
lists event messages categorized by module. Each section lists status
messages associated with each module and an event description of each message.
Table A-6. Clock Module Event Messages
Event Message
Event #
Event Description
Install, Clock Module
129
Module installation
Remove, Clock Module
130
Module removal
Enable, Clock Module, COML\
131
Module enabled
Disable, Clock Module, COML\
132
Module disabled
Restart, in 5 seconds, COML\
133
User requesting for a module to reboot
Cannot Enable, Clock Module, COML\
134
Inability to enable module
Clk Select
144
Which clock module is selected to generate
output
Software phase lock loop
(Soft PLL, Acquire/Lock/Hold)
145
Software Phase Lock Loop in Acquire, Lock,
or Holdover status
Inp Select, 1A04-02\
146
An Input has been selected as Reference
Output Pql, 2
(PQL value 1 to 5 ST2, or 8 ST3)
147
The Output PQL has been set to the value
shown
CLK C Sel, 1A04-02\
148
A reference Input has been selected as an
output source
Warmup Chg, 1800 sec, COML\
194
The user has changed the Oscillator
warmup time setting
Start tc, 240, COML\
195
The user has changed the Starting Time
Constant (TAU) of the Oscillator
Dflt tc, 10000, COML\
196
The user has changed the Default Time
Constant (TAU) of the Oscillator
Clk AR< On, COML\
199
The user has changed the Clock
Auto-Return (ON | OFF)
Inp Switch, AR On, COML\
200
The user has changed Input Auto-Return
(ON | OFF)
LO, Dis, COML\
201
The user has changed the Local Oscillator
Output (ON | OFF) on the LO Output
connector
Inp Sel Mode, PQL, COML\
202
Reference selection mode (Priority Quality
Level – PQL)
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...