12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 119
Maintenance and Troubleshooting
Troubleshooting
Fault LED on oO
Loose module
Reseat module.
Loss of signal to output module
Reseat or replace input module (or
clock module if necessary).
Line fault
Remove the Tx Cable
Improper redundancy
configuration
Adjust accordingly.
Main shelf:
left slot = even
right slot = odd
Expansion shelf:
left slot = odd
right slot = even
Fault LED on
Output module is
flashing amber
Fault on distribution cabling
Verify cabling is connected properly.
Replace cabling.
No LED lit on
modules
Power supply failure
Check connection to power supply.
Blown fuse
Replace module.
No alarms being
reported when
there is an alarmed
condition
Compromised firmware
Press RST on Comms module front
panel.
Faulty Comms module
Replace Comms module.
Alarmed module is faulty
Replace module.
Loss of power from
Expansion shelf
No power to unit
Check to ensure that UPS (if applicable)
is operating correctly.
Both A and B fuses on Expansion
shelf are blown
Remove fuses and replace.
Loss of ground
Re-attach ground wires.
Loose power cabling to
Expansion shelf
Check that power cables to unit are
securely fastened.
Expansion shelf is faulty
Call Symmetricom Global Services.
Loss of signal from
Expansion shelf
D clock not connected; loose
SDU cable to the expansion shelf
Check SDU cable and connect D clock.
Any amber source
LED on the Output
module
Loss of clock signal
Ensure clock modules are inserted
properly.
Clock modules are in warmup
mode
No action necessary.
Table 5-3. SSU-2000 Troubleshooting Procedures (Continued)
Symptom
Probable Cause
Troubleshooting
Procedure/Corrective Action
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...