12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 127
Clock Module Reference Data
Stratum 2E Clock Module
Functional Specifications
lists the specifications for the Stratum 2E Clock module.
Warmup
Amber
On = Clock module is in warm-up mode
Off = Clock module has completed warmup
Acquire
Green
On = Clock module is acquiring a lock on a signal
Off = Not acquiring a lock on a signal
Locked
Green
On = Clock module is locked on a signal
Off = Clock module is not locked on a signal
Holdover
Amber
On = Clock module is in Holdover mode of operation
Off = Clock module is not in Holdover mode
Table 6-2. Stratum 2E Clock Module Specifications
Performance Characteristic
Specification
Free Running Accuracy
Within ±5 x 10
-10
the first year
Within ±5 x 10
-9
after 10 years
Holdover Stability (Rubidium LO)
0 to 24 hrs, @ +10 to +50
°
C
0 to 24 hrs, @ 0 to +50
°
C
30 days @ +10 to +40
°
C
30 days @ 0 to +50
°
C
±9 x 10
-11
±1 x 10
-10
±1.5 x 10
-10
±1.7 x 10
-10
Numeric Controlled Oscillator
(NCO) PLL lock range
±5 x 10
-4
Tuning Resolution (Locked Mode)
<1 x 10
-13
Warm-up Time (Warm-up Mode)
20 minutes
Wander Output (Holdover)
Includes effects of all SSU-2000 modules:
Compliant with clock levels per ITU-T G.812, T1.101-1999,
and Telcordia Technologies GR-378-CORE and
GR-1244-CORE. Meets SONET requirements per T1.105.
Meets or exceeds performance requirements for ITU-T
G.812 Type II and ETSI Transit Node clocks and T1.101 and
Telcordia Technologies (Bellcore) Stratum 2 clocks.
Jitter (Locked or Holdover)
< 4 ns p-p (measured at the CLKA/BIN 8kHz output)
Table 6-1. Stratum 2E Clock Module Status LED Indicators (Continued)
Indicator
Color
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...