12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 167
Input Module Reference Data
Composite Clock Input Module
Status LED Indicators
The CC Input module is equipped with four status LEDs as shown in
. The
LED status assignments are described in
.
Figure 7-8.
Front Panel of the Composite Clock Input Module
Table 7-11. Composite Clock Input Module Status LED Indicators
Indicator
Color
Description
POWER
Green
On = The module is rec5 vDC
STATUS
Green/Amber
Green = Unit is in Normal mode of operation; no faults
Amber = Fault condition detected
Blinking = Disabled or firmware upgrade in progress
REF
Green
On = Selected as the input reference
Off = Not selected as input reference
INPUT
Green/Amber
On (Green) = Valid reference is connected
On (Amber) = Internal port fault
Blinking (Amber) = External port fault (LOS, BPV density)
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...