12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 261
Event Messages
LBO, Port[2-3], 266 ft, COML
194
Line build out on ports 2 and 3 set to 266 ft.
SlipCount, Port[2-3], 4, COML
196
Slip count on ports 2 and 3 set to 4
BpvErr, Port[2-3], Clr, COML
197
Clear BPV accumulated error count
RefFlt, Port[2-3], Off, COML
198
Reference Fault Strategy for CTA Action
disabled
Circuit ID, Set
199
Port Circuit ID set
Err Delay, (0), 10 sec, COML
251
An alarm delay time change
Alm Level, (1), Min, COML
252
An alarm level change
Setup, Factory, COML
254
User defaults have been set and saved
Table A-10. Output Module Event Messages
Event Message
Event #
Event Description
Install, Output Module\
129
Module Installation
Remove, Output Module\
130
Module Removal
Enable, Output Module, COML\
131
Output module has been enabled
Disable, Output Module, COML\
132
Output module has been disabled
Restart, in 5 seconds, COML\
133
Module re-boot
Cannot Enable, Output Module, COML\
144
Output module cannot be enabled
Frame Mode, ESF, COML\
193
Output framing type change
ZS, On, COML\
194
User changed output framing type
DS1 LEN, [0-5], len=133 ft., COML\
195
User changed output line length (DS1 only)
CRC, On, COML\
199
User has changed output framing type
SSM Bit, 8, COML\
201
User has changed output SSM bit position
(E1 only)
Min Clk Level, ACQ, COML\
202
User has changed Minimum Clock Level to
turn on outputs
Bypass, On, COML\
203
User has changed Bypass mode of
operation
DutyCycle, Port= [0-1], 50/50, COML\
204
CC signal duty cycle settings have been
changed for the port shown
Delay, Port= [0-3], 4000ft, COML\
205
CC signal phase offset settings have been
changed for the port shown
Table A-9. LRM Event Messages (Continued)
Event Message
Event #
Event Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...