12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 293
TL1 Command Interface
RTRV-PRMTR-COMM:[tid]:[aid]:
ctag;
Valid aid code:
ALL
,
COML
,
COMA
,
COMB
,
TELNET
, or
TL1
This command returns the current serial protocol settings for
the unit.
When a serial port is specified, the format of the response
message is:
^^^"aid:baud,echo,eol,mode,tout"<cr lf>
where:
aid
= communication port [COML |COMA|COMB]
baud
= communications baud rate
[19200|9600|4800|2400|1200]
echo
= determines if the port operates in full-duplex or
half-duplex [ON|OFF]
eol
= end-of-line character to be used when the unit
transmits ASCII data [CR|LF|CRLF]
mode
= mode of communication [ASCII|TL1]
tout
= inactivity timeout period before the session is
logged out [value |NEVER]
When a Telnet port is specified, some data fields are null,
and the format of the response message is:
^^^"aid:,,,,tout"<cr lf>
RTRV-PRMTR-ELTIME:[tid]:[aid]:
ctag;
Valid aid code:
SxAy
This command returns the time for alarm elevation, from 60
seconds to 500,000 seconds. A setting of 0 (zero) means no
elevation for the alarm. When an alarm has been at MINOR
or MAJOR level continuously for
elevtime
seconds, then it
is elevated to the next level. Delay may be set for each
module or ALL modules, and applies to all alarms created by
the module.
^^^"aid:elevtime" <cr lf>
where:
elevtime
= alarm elevation time for the specified
module.
RTRV-PRMTR-FREQ:[tid]:[aid]:
ctag;
Valid aid code:
ALL
,
S1Ay-z
This command returns the MTIE threshold settings for the
DS1/E1 input port designated by the aid.
The format for the response message is:
^^^"aid:freq,fae,fac,fbe,fbc,fatau,fbtay" <cr lf>
where:
aid
= access identifier of the port
fae
= frequency error threshold for A
fac
= clear threshold for A
fbe
= error threshold for B
fbc
=
clear threshold for C
fatau = frequency error for A
fbtau = frequency error for B
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...