12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 279
TL1 Command Interface
RTRV-DATA-LRMBPV:[tid]:[aid]:
ctag;
Valid aid code:
ALL
,
SxA[y[-z]]
This command returns the BPV data (current operating
mode and status) of an LRM module or port. The format of
response message is:
^^^"aid:ttime,60srate,24hrate,es,ses,sesr" <cr lf>
where:
module
aid
and the port
ttime
accumulates how much time (integer) in seconds
since the last BPV Clear command was issued
60srate
= BPV error rate (float value) per second in a
60-second window
24hrate
= BPV error rate (float value) per second in an
86400-second window
es
indicates (integer) that the BPV accumulates BPV
Errored Seconds (BPV-ES) when any seconds have a
BPV error
ses
indicates (integer) that the BPV accumulates BPV
Severely Errored Seconds (BPV-SES) when any
seconds have a severely BPV error
sesr
= BPV Severely Errored Ratio (float value).
Table B-5. TL1 Retrieve Commands (Continued)
Command
Description
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...