12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
81
Installing the SSU-2000
Handling Modules
7. Insert the new module into slot 3 of the main shelf. Tighten the captive screws
on the front panel of the module. Wait for the “
module installed
” message to
appear.
8. Enable the module using either TL1 or ICS commands.
ICS command:
Type
CONFIG 1A3 ENABLE
, then press
Enter
.
TL1 command:
ACT-MODULE::S1A3:123;
9. Verify that the module is entered in the registry.
ICS command:
Type
CONFIG
, then press
Enter
.
TL1 command:
RTRV-INV:::123;
Disabling a Module
Use this command to temporarily disable a module without removing it from the
SSU-2000 registry. All outputs from the disabled module will turn off, unless a
summer adapter is installed on the I/O connector on the rear panel of the shelf. The
example commands are for slot 3 in the main shelf.
1. Connect to the SSU-2000 using one of the methods described in
, on page 88. The system prompts for a user
name.
2. Log in to the system using your user name and password.
3. Disable the module using either ICS or TL1 commands.
ICS command:
Type
CONFIG 1A3 DISABLE
, then press
Enter
.
TL1 command:
DISC-MODULE::S1A3:123;
Note:
Be sure that the I/O Adapter port is of the proper type and
impedance for the new module.
Caution:
To avoid possible damage and intermittent failures, ensure
that you have completely inserted the module into the system and
that you have securely tightened the captive screws.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...