12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide 113
Maintenance and Troubleshooting
Corrective Maintenance
Corrective Maintenance
The SSU-2000 and SDU-2000 have a modular design and field service is limited to
replacing the FRUs (field replaceable units) identified in
and
These tables also outline possible component problems and corrective action. Refer
to
, on page 121, for information on re-ordering, re-packing,
or returning equipment to the factory.
Warning:
To avoid serious personal injury or death, exercise
caution when working near high voltage lines. In particular:
Use extreme caution when installing the GPS antenna near,
under or around high voltage lines.
Follow local building electrical codes for grounding the antenna
system that is used with the SSU-2000.
Caution:
For continued fire protection, fuse the interface “A” power
feeds at the power distribution source for (5A
---
vDC).
This unit must be grounded. Refer all servicing to qualified
personnel.
Caution:
For continued EMC compliance, replace all deformed
module gaskets with the same type. Clean gaskets and mating
surfaces.
Secure all modules with captive screws.
Caution:
To maintain EMC compliance, use only properly shielded
cabling on all telecom signal wiring, including I/O, clocks, and
Ethernet connections. Ensure that connections are appropriately
grounded.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...