Provisioning and Operating the SSU-2000
Overview of the SSU-2000 Security System
100
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Changing Factory Defaults
Use the following steps to change the factory default or any configuration settings in
the SSU-2000. This example changes an alarm from minor to major.
1. Connect a computer to the SSU-2000 using the procedure in
SSU-2000>
prompt appears.
2. Log in to the SSU-2000:
ICS command:
Type
login
followed by the administrator’s user name and press
Enter
. The
system prompts for a password. Type the administrator’s password and press
Enter
. The system prompt
SSU-2000>
appears.
TL1 command:
Type
ACT-USER::uid:123::pwd;
where
uid
and
pwd
are the administrator’s
user id and password, respectively; 123 is an arbitrary ctag value.
3. Type
alarm 1A12 03
(1=shelf; 12=slot; 03=alarm number), and press
Enter
.
4. Type
alarm 1A12
and press
Enter to
verify that 03 changed to major.
5. Type
bye
and press
Enter
to log off the system.
Customizing Other Configuration Options
The SSU-2000 allows you to change any or all configuration settings. Use the
following procedures to customize the system for a particular environment.
1. Connect a computer to the SSU-2000 using the procedure in
SSU-2000>
prompt appears.
2. Log in to the SSU-2000:
ICS command:
Type
login
followed by the administrator’s user name and press
Enter
. The
system prompts for a password. Type the administrator’s password and press
Enter
. The system prompt
SSU-2000>
appears.
TL1 command:
Type
ACT-USER::uid:123::pwd;
where
uid
and
pwd
are the administrator’s
user id and password, respectively; 123 is an arbitrary ctag value.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...