Interactive Command Set
362
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
PQLTABLE
Use this command to display or change user-defined Priority Quality Level (PQL)
code and text string.
Level 0
Not applicable
Level 1
PQLTABLE
Use this command to display the PQL table setting.
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
PQLTABLE FACTORY
PQLTABLE pql# [{DS1|E1}] UNUSED
PQLTABLE pql# [{DS1|E1}][SSM n][DESC str] [STD{ON|OFF}]
Use this command to read or set current PQL translation table
information. This table provides the translation from the internal
Priority Quality Level (PQL) to the Synchronization Status Message
(SSM) for the various framing types.
Options are:
FACTORY
Use this option to set factory defaults for the table. Both
DS1 and E1 are affected.
Pql#
PQL number for the entry. The range is 1 to 16.
DS1|E1
Use this option to specify which entry to affect. If you do
not specify this information, both entries are assumed.
UNUSED
Marks this entry as unused in the table
SSM n
Use this option to set the SSM value to use for the
framing type by specifying a hex number, preceded by
0x
.
DESC str
Use this option to set the descriptive text string for this
entry. Use a maximum of 14 characters. You can
enclose the string in double quotes to allow entry of
spaces and lower-case letters.
STD {ON|OFF}
Use this option to set or clear this entry as the
standard input type. Only
standard
entries are matched
for input.
Level 4
Same as Level 3 operation
Remarks
None
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...