12713020-002-2 Revision D – April 2004
SSU-2000 User’s Guide
51
Product Overview
Overview of SSU-2000 Operation
Overview of SSU-2000 Operation
After initial installation and configuration is completed, the SSU-2000 is capable of
unattended operation. After power-up, where the external power supplies are turned
on so that they supply power to the main shelf, the SSU-2000 performs a
self-diagnostic test routine and properly initializes the hardware. Any active Alarms
are time tagged and reported as Events. All Events are time tagged and the last 500
Events are stored in NVRAM. All Events can be remotely accessed and cleared by
a user with the appropriate security level. Several optional levels of password
protection are available for system protection as described in
After the internal oscillators on any installed Clock modules have warmed up, the
SSU-2000 enters the ACQUIRE mode to phase lock the oscillators to the external
references. After the SSU-2000 reaches the LOCKED mode on at least one of the
Clock modules, any change of state is reported as an Event.
Synchronization Status Messages (SSMs)
The SSU-2000 supports input and output SSMs. SSMs provide a method for
providing clock quality information to any equipment that uses synchronization
inputs.
Table 1-3
describes the ANSI SSM values and the traceability associated
with each value.
Table 1-4
describes the ITU SSM values and the traceability
associated with each value.
Table 1-3. ANSI SSM Quality Level Definitions
Description
Quality
Level
Abbreviation
Stratum 1 Traceable
1
PRS
Synchronized – traceability unknown
2
STU | UNK
Stratum 2 traceable
3
ST2
Transit Node traceable
4
TNC | TYPE I
Stratum 3E traceable
5
ST3E | TYPE III
Stratum 3 traceable
6
ST3 | TYPE IV
SONET Minimum Clock traceable
(20 ppm clock)
7
SMC
Stratum 4 traceable
8
ST4
Do Not Use for synchronization
9
DUS
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...