SSU-2000 Shelf Specifications
444
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Number of Outputs
20 per module
Termination Impedance
120
Ω
± 5%
Composite Clock Signals (64 kbit/s)
Signal Waveshape
Duty Cycle
Rise Time
Pulse Width
Pulse Interval
Amplitude
Termination Impedance
Rectangular (62.5% or 50/50 duty cycle), software selectable, per
G.703 Sec. 4 and GR-378
5/8 (62.5%)
50/50
< 500 nsec < 500 nsec
9.8 µS
±
5% 7.8125 µS
±
5%
15.625 µS
±
5% 15.625 µS
±
5%
2.7 to 5.5 V peak 1.0
±
0.1 V
133
Ω
±
5% 110
Ω
Number of Outputs
20 per module
2048 kHz Clock Signals
Signal Waveshape
Rise Time
Fall Time
Duty Cycle
Per ITU Rec. G.703 Sec. 13
Square wave
< 50 nsec
< 50 nsec
50%
±
5%
Amplitude
1.0 to 1.9 volts peak into 120
Ω
.75 to 1.5 volts peak into 75
Ω
Jitter
< 0.03 UI
Number of Outputs
20 per module
Termination Impedance
120
Ω
± 5% or 75
Ω
± 5%
Table F-6. Output Signal Specifications (Continued)
Parameter
Specification
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...