Provisioning and Operating the SSU-2000
Checking Alarm Status
98
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
Saving the Provisioning Setup
After you provision each module, you can save the setup in the Communications
module memory.
ICS command:
Type
SET SAVE
, then press
Enter
.
TL1 command:
SET-PRMTR-SETUP::ALL:123::SAVE;
Checking Alarm Status
All alarm indication lights should be extinguished and the POWER indication lights
should be green after completing the power up sequence. The valid input reference
alarm clears, rubidium lock clears, frequency alarms clear, and the ACQUIRE LED
is ON. Use the following procedure with the STATUS and ALARM commands to
verify that the unit is operational.
1. Connect a computer to the SSU-2000 using the procedure in
SSU-2000>
prompt appears.
2. Log in to the SSU-2000:
ICS command:
Type
login
followed by the administrator’s user name and press
Enter
. The
system prompts for a password. Type the administrator’s password and press
Enter
. The system prompt
SSU-2000>
appears.
TL1 command:
Type
ACT-USER::uid:123::pwd;
where
uid
and
pwd
are the administrator’s
user id and password, respectively; 123 is an arbitrary ctag value.
3. Type
alarm
and press the
Enter
key to verify that there are no active alarms.
4. Type
bye
and press the
Enter
key to log off the system.
Overview of the SSU-2000 Security System
The SSU-2000 security system software contains a hierarchy of user levels that
permit an increasing level of access to system parameters. This allows the system
administrator to add users that can, for example, view but not change system
parameters; other users can view and change system parameters.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...