SNMP Protocol
386
SSU-2000 User’s Guide
12713020-002-2 Revision D – April 2004
The MIB is controlled by the SSU-2000’s SNMP agent. The SNMP agent is a server
program that sends SSU-2000 status (stored in the MIB database) to the network
manager when the manager transmits
GET
or
GET NEXT
commands. The manager
can also transmit
SET
commands that instruct the agent to set MIB variables to new
values. The
TRAP
command sets up a communication link that allows the server to
send the manager indications of MIB occurrences, such as a fault condition.
Enabling SNMP
To use the TL1 command to enable SNMP and have the unit transmit all alarms and
events, type:
SET-PRMTR-SNMP-MODE:::::ENA,ALL;
To use the ICS command to enable SNMP and have the unit transmit all alarms and
events, type:
SNMP ENABLE
and press
ENTER
.
Adding a User
TL1 Command
To use the TL1 command to add user XYZ with MD5 authentication using algorithm
HMAC-MD5 with the 16 character authentication key, a 16 character privacy key,
and user level 3, type:
SET-PRMTR-SNMPV3-USER:::::ADD,XYZ,MD5,123456789ABCDEFG,
123456789ABCDEFG,3;
ICS Command
To use the ICS command to add user XYZ with MD5 authentication using algorithm
HMAC-MD5 with the 16 character authentication key, a 16 character privacy key,
and user level 3, type:
SNMP USER ADD XYZ
and press
ENTER
.
At the prompt, type
123456789ABCDEFG
(a 16 character authentication key) and
press
ENTER
.
At the prompt, type
123456789ABCDEFG
(a 16 character privacy key) and press
ENTER
.
Note:
Valid authentication key and privacy key characters include
numbers, upper and lowercase letters, and the character set
":;<=>?@". The semicolon functions properly only in ICS mode, and
the colon must be enclosed in quotes in TL1 mode, as “
USER:NAME
”
or
“
PASS:WORD
”. To enter lowercase letters, enclose the input in
quotes, as “
UserName
”
or
“
PassWord
”.
Do not
use spaces in
usernames.
Содержание SDU-2000
Страница 12: ...12 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 18: ...18 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 142: ...Clock Module Reference Data Communications Module 142 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 172: ...Input Module Reference Data Input Adapter Panels 172 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 222: ...Output Module Reference Data Output Adapter Panels 222 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 390: ...SNMP Protocol 390 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 420: ...I O Connector Grounding 420 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...
Страница 434: ...User Changes to Factory Defaults 434 SSU 2000 User s Guide 12713020 002 2 Revision D April 2004 ...