- 41 -
No.JXC#-OMX0009-A
・
JOG motion data addresses (motion parameter items)
Controller memory
address
Name
Word
Setting data range
Unit
(0030)h
JOG speed
1
*1
)
1mm/s
(0031)h
JOG acceleration
1
1 to “Max ACC/ DEC” of the basic
parameter
1mm/s
2
(0032)h
JOG deceleration
1
1 to “Max ACC/ DEC” of the basic
parameter
1mm/s
2
(0033)h
JOG thrust
1
*1
)
1%
(0034)h
Fixed distance
2
“Stroke (-) ” to “Stroke (+) ” of the
basic parameter
0.01mm
・
Step data address
Controller memory
address
Name
Word
Setting data range
Unit
(0400)h to (040F)h
Step data (No.0)
16
-
-
(0410)h to (041F)h
Step data (No.1)
16
-
-
(0420)h to (042F)h
Step data (No.2)
16
-
-
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
(07F0)h to (07FF)h
Step data (No.63)
16
-
-
Please refer to the example of the following in a detailed address of each step data.
Example) Address for step data No.0
Controller memory
address
Name
Word
Setting data range
Unit
(0400
)h
Movement MOD
1
0
=
Disable 1
=
ABS 2
=
INC
-
(0401
)h
Speed
1
*1
)
1mm/s
(0402
)h
Position
2
“Stroke (-) ” to “Stroke (+) ” of the
basic parameter
0.01mm
(0404
)h
Acceleration
1
1 to
“Max ACC
/ DEC” of the basic parameter
1mm/s
2
(0405
)h
Deceleration
1
1 to “Max ACC
/ DEC” of the basic parameter
1mm/s
2
(0406
)h
Pushing force
1
*1
)
1%
(0407
)h
Trigger LV
1
*1
)
1%
(0408
)h
Pushing speed
1
*1
)
1mm/s
(0409
)h
Moving force
1
*1
)
1%
(040A
)h
Area 1
2
“Stroke (-) ” to “Stroke (+) ” of the
basic parameter
0.01mm
(040C
)h
Area 2
2
“Stroke (-) ” to “Stroke (+) ” of the
basic parameter
0.01mm
(040E
)h
In position
2
*1
)
0.01mm
*1) The input range which can be set differs depending on the electric actuator type.