- 57 -
No.JXC#-OMX0009-A
●To upper level device from the controller [IN] (to base module from the remote module) -
continued
PLC memory
address
RWw data name
Content
RWr
bit
Half numerical
data
instructions
Full
numerical
data
instructions
5
F to
0
L
R
et
urn
of
D
at
a
ed
itin
g
Address
(always
0)
Target
position
● Half numerical data instructions
0 is always output.
● Full numerical data instructions
The target position of the electric actuator is shown
in multiples of 0.01 mm when numerical data reading
is enabled.
6
F to
0
H
DATA(H)
● Half numerical data instructions
Data that corresponds to the executed instruction code
is output.
An error code is output when there is an abnormality.
● Full numerical data instructions
The target position of the electric actuator is shown
in multiples of 0.01 mm when numerical data reading
is enabled.
7
7 to 0
DATA(L)
Alarm 1
● Half numerical data instructions
Data that corresponds to the executed instruction code
is output.
00h is output when there is an abnormality. *
3)
● Full numerical data instructions
Alarm code shown as a 3 digit decimal number when
numerical data reading is enabled and an alarm is
generated. In the half numerical data instruction mode,
up to two alarms can be output. In the full numerical
data instruction mode, up to four alarms can be output.
The latest alarm code generated will be output to alarm
1. Alarm is updated by another alarm. The code of the
previous alarms generated will be shifted to
alarm1
→
2
→
3
→
4.
When the number of alarms generated exceeds the
maximum alarm output for each mode, the oldest
alarm code is deleted from the record.
Example)
Alarms were generated in order of (1)
→
(5)
Alarm 1
(The latest)
(1)
(2)
(3)
(4)
(5)
Alarm 2
0
(1)
(2)
(3)
(4)
Alarm 3
0
0
(1)
(2)
(3)
Alarm 4
0
0
0
(1)
(2)
(1) to (5) in the table indicate the codes for the generated
alarms.
Please refer to
"16.2 Alarm details"
for the alarm
details.
F to 8
Alarm 2
8
7 to 0
Alarm 3
F to 8
Alarm 4
9
F to 0
Sub
Function
The executed instruction code is output. Please refer to
“9.5 Data editing function"
for details of the instruction
code.
The value of 80h that is the OR (logical add) is output
to Sub Function which set in RWw1.
*3)
10
F to 0
Address
The start address of the executed instruction code is
output. Please refer to
“9.5 Data editing function"
for
details of the instruction code.
00h is output in abnormal conditions.
*3)
11
F to 0
Address
(always 0)
0 is always output