- 77 -
No.JXC#-OMX0009-A
[2] Positioning operation
- Procedure -
- Timing chart Positioning operation -
①
Input step data No. (“IN0” to “IN5”)
↓
②
Turn ON the "DRIVE".(OUT0 to OUT 5 is
turned off)
→Scan the step data number (From IN0
to IN5). Then, if DRIVE is turned OFF,
the step data number will be output
(From the output OUT0 to OUT5)
↓
③
"BUSY" turns ON.
(and the positioning movement starts.)
↓
④
When "INP" turns ON and "BUSY"
turns OFF, the positioning operation will
be completed.
[3] Pushing Operation
- Procedure -
- Timing chart Pushing Operation -
①
Input step data No.
(“IN0” to “IN5”)
↓
②
Turn ON the "DRIVE".
(OUT0 to OUT5 is turned off.)
→Scan the step data number (From IN0 to
IN5).
After this, if DRIVE is turned OFF, the
step data number will be output (From the
outputs OUT0 to OUT5)
↓
③
“BUSY” is ON when pushing starts
↓
④
When “INP” turns ON and
“BUSY” turns OFF, the pushing
operation will be completed
(the actuator generates the force larger than
that specified in "Trigger LV" of the step
data).
Power
IN0
~
5
SVON
DRIVE
OUT0
~
5
BUSY
SVRE
SETON
INP
External Lock
Electric actuator
Input
Output
Speed
Scan the step data no.
If the electric actuator is w ithin the "In position" tange,
INP w ill be turned ON but if not, it w ill remain OFF.
Output the step data no.
0mm/s
24V
0V
OFF
ON
ON
OFF
ON
OFF
・
・
・
・
・
・
・
・
・
・
・
・
・
Input the step data no
.
Min15m
Power
IN0
~
5
SVON
DRIVE
OUT0
~
5
BUSY
SVRE
SETON
INP
External Lock
Output
Input
Speed
Electric actuator
Positioning
operation
If the electric actuator is w ithin the "In position" range,
INP w ill be turned ON but if not, it w ill remain OFF.
Scan the step data no.
Output the step
data no.
24V
0V
OFF
ON
ON
OFF
ON
OFF
0mm/s
・
・
・
・
・
・
・
・
・
・
・
・
Min15m
Input the step data no.