- 59 -
No.JXC#-OMX0009-A
11. Settings and Data Entry
In order to move the electric actuator to a specific position, it is necessary to setup the patterns of
operations with a PC (with the controller setting software) or the teaching box or record data. This setup
data input by the software or teaching box will be recorded in the memory of the controller.
For the controller setting software and the teaching box, there are two available modes.
You can select the appropriate one depending on the operation.
•Easy mode
In Easy mode, the actuator can be started by entering only a limited number of settings with the
controller setting software and the teaching box.
The combination of settings you need to set up will change depending on the type of actuator.
(A combination of data can be selected).
•Normal mode
In Normal mode, a more detailed setup can be made (conditions for actuator and controller, etc.)
than in Easy mode.
Three kinds of setting data can be changed in this mode; "Step data", "Basic parameter" and
"Return to origin parameter".
11.1 Step Data
A "step data" is the setting data mainly describing the movement of the actuator. Total 64 step data (12
attributes per step) can be handled with this controller. Each step data will become effective as soon
as it is recorded into the controller.
E.g.) Step data on the PC (controller setting software) screen [Normal mode]
No.
Movement
mode
Speed
[mm/s]
Position
[mm]
Acceleration
[mm/s
2
]
Deceleration
[mm/s
2
]
Pushing
force
[%]
Trigger
LV
[%]
Pushing
speed
[mm/s]
Moving
force
[%]
AREA 1
[mm]
AREA 2
[mm]
In
position
[mm]
0
ABS
100
20.00
1000
1000
0
0
0
100
18.00
22.50
0.5
1
ABS
50
10.00
1000
1000
70
60
5
100
6.0
12.0
1.5
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
┆
63
ABS
20
5.00
500
500
0
0
0
100
3.0
8.0
1.2
Caution