- 46 -
No.JXC#-OMX0009-A
(4) Higher level device
→
Controller [OUT] (Master to Remote)
PLC
Memory
address
Signal name
Description
Ry
Single
numerical data
instructions
Half numerical
data
instructions
Full numerical
data instructions
00
IN0
Bit no. to specify the step data
(Specify the number by combining On/Off of the
terminals.)
E.g.) Step data No. 3 has been assigned.
IN5
IN4
IN3
IN2
IN1
IN0
OFF
OFF
OFF
OFF
ON
ON
01
IN1
02
IN2
03
IN3
04
IN4
05
IN5
06
-
Set always OFF(0)
07
-
Set always OFF(0)
08
HOLD
If “HOLD” is turned ON during operation, the speed
decreases at maximum deceleration set in the basic
parameters until the actuator stops. The remaining
stroke will be on hold as long as “HOLD” is ON and
when “HOLD” is turned OFF, the actuator restarts and
travels for the remaining stroke.
- When “DRIVE” or “SETUP” is ON
Caution
・
As long as HOLD is ON, the DRIVE input will be
disabled.
・
The signals are rendered invalid whilst “HOLD” is
in operation.
09
SVON
“SVON” signal turns the servo motor ON.
When “SVON” is ON, the servo motor will be turned
ON. When it is OFF, the servo motor will be turned
OFF.
0A
DRIVE
When “DRIVE” is turned ON, the system scans “IN0”
to “IN5” and starts the operation of the actuator.
Then, when “DRIVE” is turned OFF, the number of the
active step data will be output via the “OUT0” to “OUT5”
signals.
0B
RESET
“RESET” is a signal to reset the alarm and the
operation.
After “RESET”, the speed decreases at maximum
deceleration of the basic parameter until the actuator
stops.
“INP” and “OUT0” to “OUT5” will be turned OFF (however,
if the actuator is stopped within the in-position range, “INP”
will turn ON).
0C
SETUP
When “SVRE” is ON, the “SETUP” operation (return to
origin operation) will be performed. During the “SETUP”
operation, “BUSY” will turn ON. After completion of the
“SETUP” operation, “SETON” and “INP” will turn ON.
DRIVE
or
SETUP
HOLD
ON
OFF
ON
OFF
On hold
Restart
Speed