- 56 -
No.JXC#-OMX0009-A
1
F to 0
L
Current position
The current position of the electric actuator is shown in
multiples of 0.01 mm when numerical data reading is
enabled.
Example)
800.00mm (80000d
=
13880h) is output:
RWr1
=
3880h
RWr2
=
0001h
2
F to 0
H
3
7 to 0
L
R
et
urn
of
D
at
a
ed
itin
g
Sub
Function
Current
speed
● Half numerical data instructions
The executed instruction code is output. Please refer
to
“9.5 Data editing function"
for details of the
instruction code. The value of 80h that is the OR
(logical add) is output to Sub Function which set in
RWw1.
*3)
● Full numerical data instructions
The current speed of the electric actuator is shown in
multiples of 1 mm/s when numerical data reading is
enabled
Example) 300 mm/s (300d=012Ch) is output
RWr3
=
012Ch
F to 8
H
4
7 to 0
L
Address
Current
Force
● Half numerical data instructions
The start address of the executed instruction code is
output. Please refer to
“9.5 Data editing function"
for details of the instruction code
00h is output in abnormal conditions.
*3)
● Full numerical data instructions
The current pushing force of the electric actuator is
shown in multiples of 1% when numerical data
reading is enabled.
F to 8
H
H=Most Significant Byte or upper word
L=Least Significant Byte or lower word