- 100 -
No.JXC#-OMX0009-A
(7) When the actuator is operated manually (when “SVRE” signal is OFF), supply 24VDC to the
[LK RLS] terminal of the power supply connector.
If the product is operated without releasing the lock, wear of the lock sliding surface will be
accelerated, causing a reduction in the holding force and the life of the locking mechanism.
(8) Do not supply 24VDC power supply constantly to the [LK RLS].
Only supply 24VDC power supply to the [LK RLS(Lock release)] terminal during normal operation. If
power is supplied to the [LK RLS] terminal continuously, the lock will be released, and workpieces
may be dropped at stop (EMG).
20. Controller and Peripheral Devices/Specific Product Precautions
20.1 Design and Selection
Warning
(1) Use the specified voltage.
Otherwise, malfunction and damage to the controller may result.
If the applied voltage is lower than the specified voltage, it is possible that the load cannot be moved
due to an internal voltage drop. Check the operating voltage before use.
(2) Do not operate beyond the specifications.
Fire, malfunction or actuator damage can result. Check the specifications before use.
(3) Install an emergency stop circuit.
Install an emergency stop outside of the enclosure so that it can stop the system operation
immediately and intercept the power supply.
(4) In order to prevent danger and damage due to the breakdown and the malfunction of this
product, which may occur at a certain probability, a backup system should be established in
advance by giving a multiple-layered structure or a fail-safe design to the equipment, etc.
(5) If fire or personal injury is expected due to abnormal heat generation, ignition, smoking of
the product, etc., cut OFF the power supply for this product and the system immediately.
20.2 Handling Precautions
Warning
(1) The inside of the controller and its connector should not be touched.
It may cause an electric shock or damage to the controller.
(2) Do not perform operation or setting of this equipment with wet hands.
It may cause an electric shock.
(3) A product that is damaged or missing any components should not be used.
Electric shock, fire, and injury can result.
(4) Use only the specified combination of controller and electric actuator.
It may cause damage to the controller or the actuator.
(5) Be careful not to be caught or hit by the workpiece while the actuator is moving.
It may cause an injury.
(6) Do not connect the power supply to the product until it is confirmed that the workpiece
movement area is safe.
The movement of the workpiece may cause an accident.