- 58 -
No.JXC#-OMX0009-A
12
F to 0
DATA(H)
The data of the executed instruction code is output.
Error code is output in abnormal conditions.
*3)
13
F to 0
DATA(L)
The data of the executed instruction code is output.
00h is output in abnormal conditions.
*3)
14
F to 0
Occupation
area
-
15
F to 0
H=Most Significant Byte or upper word
L=Least Significant Byte or lower word
*3) When the error occurred in the data edit function by the specified address which is out of the range
etc.,
the value of 80h that is the OR (logical add) is output to Sub Function which set in RWw1 is
returned to Sub Function RWr3 (RWr9 at
Full numerical data instructions), and the received error
code is returned to DATA (H) [RWr6] (RWrC at
Full numerical data instructions). And RWr4:Address
and RWr7: DATA (L) ( RWrA and RWrD at
Full numerical data instructions) will be 00h. Error code
is shown below.
Error code
Name
Content
2
Out of
address range
1) The setting of the reading/writing start number is out of address range
2) Writing in a number (address) which is not permitted
3
Out of access
point number
range
The setting of the reading/writing final number is out of the range
●
Higher level device
→
Controller [OUT] (Master to Remote)
PLC memory
address
RWw data name
Content
RWw
bit
Half numerical
data
instructions
Full numerical
data
instructions
0
0
C
ont
ro
ller
cont
ro
l fl
ag
Setting read numerical data
Turn ON to enable reading the numerical data such as
current position or current speed. Turn OFF to disable
reading.
1
Setting parameter rewriting
When this flag is ON, the data edit function is enabled.
When OFF, operation by numerical instruction is
enabled. Before using the numerical instruction
operation, be sure to turn this flag OFF.
2
Reset flag
Turning it OFF then ON will clear the RWr0, bit5:
ALARM flag.
3
Restart flag
Turn it OFF then ON to re-initialize the controller.
4
Start flag
Data transmission flag during data edit operations.
It is OFF while waiting to transmit. Turn it ON when
transmitting parameters to the controller.
5 to F
(No used)
Set always OFF(0)
1
F to 0 S
en
d
of
D
at
a
edi
ting
Sub Function
Input the instruction code to be executed.
Please refer to
"9.5 Data edit function"
for details.
2
F to 0
Address
Input the start address of the instruction code to be
executed.
Please refer to
"9.5 Data edit function"
for details.
3
F to 0
Address(always 0)
0 is always output.
4
F to 0
DATA(H)
Input data for some instruction codes. Please refer to
"9.5 Data edit function"
for details.
5
F to 0
DATA(L)
6
F to 0
Occupation area
-
7
F to 0
8 to
15
F to 0
Occupation
area
-
H=Most Significant Byte or upper word
L=Least Significant Byte or lower word