- 63 -
No.JXC#-OMX0009-A
ORIG offset
*1)
This defines the position of the actuator after the return to origin
operation.(Unit: mm)
■
The ORIG offset is 0 (mm).
■
The ORIG offset is 100 (mm).
Caution
If the value for the “ORIG offset” is changed, the “Stroke (+)”
and “Stroke (-)” of the basic parameters should be checked.
“ORIG offset” becomes valid after the return to origin operation,
make sure that return to origin operation is performed after any
changes.
XX
Max force
*1)
The maximum force for the pushing operation (Unit: %).
XX
Para protect
1 to 2
Sets the range in which the parameter and step data can be changed.
1. Basic par Step data (Basic par Return to origin
par Step data)
2. Basic parameter (Basic par Return to origin parameter)
XX
Enable SW
1 to 2
This defines the status of the Enable switch of the teaching box.
1: Enabled
2: Disable
XX
Unit name
Fixed value
Indication of actuator type compatible with the controller.
Do not change the setting.
-
M
Actuator
In the examples on the left, the
actuator positions are not different
but the reference point that the
controller recognizes will be
changed after the return to origin
operation.
Controller recognizes
Position after return to origin
position (0mm)
M
Actuator
Controller recognizes
Position after return to origin
position (100mm)