- 111 -
No.JXC#-OMX0009-A
22. Memory map list
The memory map according to the mode is shown below. Please refer to
“
10. Memory map
”
for details
of each signal.
●Single numerical data instructions (1 Stations occupied) [Remote IO]
PLC memory
address
Signal name
PLC memory
address
Signal name
Rx
Ry
00
OUT0
00
IN0
01
OUT1
01
IN1
02
OUT2
02
IN2
03
OUT3
03
IN3
04
OUT4
04
IN4
05
OUT5
05
IN5
06
-
06
-
07
-
07
-
08
BUSY
08
HOLD
09
SVRE
09
SVON
0A
SETON
0A
DRIVE
0B
INP
0B
RESET
0C
AREA
0C
SETUP
0D
WAREA
0D
JOG(-)
0E
ESTOP
0E
JOG(+)
0F
ALARM
0F
FLGTH
1A to 10
CC-Link system area
1F to 10
CC-Link system
area
1B
Remote station
READY
1F to 1C
CC-Link system area
●Single numerical data instructions (1 Stations occupied) [Remote register]
PLC memory
address
RWr Data name
PLC memory
address
RWw Data name
RWr
bit
RWw
bit
0
0
Return of Occupied number of stations(L)
0
0
Setting read numerical data
1
Return of Occupied number of stations(H)
1
(No used)
Set always OFF(0)
2
Sending
2
Reset flag
3
Sending completed
3
Restart flag
4
READY
4
Movement MOD
5
ALARM flag
5
Speed
6
Initial
6
Position
7
Return of the read
numerical data
7
Acceleration
8
(No used)
8
Deceleration
9
9
Pushing force
A
A
Trigger LV
B
B
Pushing speed
C
C
Moving force
D
Data editing error
receiving
D
Area 1
E
Parameter anomaly
detection
E
Area 2
F
The abnormal station
detection
F
In position
1
F to 0
Current position
1
0
Start flag
7 to 1
(No used)
Set always OFF(0)
F to 8
Movement MOD
2
F to 0
2
F to 0
Numerical data
instructions data
(2 word data)
*1)
Numerical data
instructions data
(1 word data)
*2)
3
F to 0
Current position
3
F to 0
(No used)
*2)
Set always OFF(0)
*1) RWw0, bit4 to F: Setting numerical data in the case of "Position" or "Area 1" or "Area 2".
*2) RWw0,bit4 to F: Setting numerical data in the case of "
Speed
" or "
Acceleration
" or "
Deceleration
" or “
Pushing force
” or “
Trigger LV
” or “
Pushing speed
” or “
Moving force
” or “
In position
”.