Connecting
6.9 Assignment of terminals and connectors
SINAMICS DCM DC Converter
186
Operating Instructions, 12/2018, A5E34763375A
NOTICE
Using the memory card
•
The memory card may only be inserted as shown in the previous figure.
•
The memory card must not be removed or inserted while data is being saved.
Procedure to safely remove the memory card, see Chapter "Operation", Section
"Memory card functions".
•
If you are returning a defective "Control Unit (CUD)" module, do not return the memory
card along with it – instead, keep it so that you can use it in the replacement module.
A memory card is not required for the standard drive operation.
The memory card is needed in the following applications:
●
Saving parameters
Parameters are saved on the memory card and can simply be copied onto a new CUD if
it needs to be replaced.
●
Firmware update
It is easy to perform a firmware update using a memory card.
●
Loading additional languages onto the Advanced Operator Panel AOP30.
●
Performing an offline long-time trace. See also Chapter "Diagnostic memory (Page 632)"
●
Loading the DCC block library into the drive
●
SINAMICS Link function: The SINAMICS Link function requires that the memory card is
always inserted.
●
Modbus TCP function: The Modbus TCP function requires that the memory card is
always inserted.
●
Saving the Diagstor.spd diagnostics file to the \USER\SINAMICS\DATA\LOG directory.
See also Chapter "Trend recorder function (Page 633)"