Commissioning
8.5 Commissioning with the STARTER commissioning tool
SINAMICS DCM DC Converter
310
Operating Instructions, 12/2018, A5E34763375A
Note
Encoder configuration using the expert list
If the existing encoder type is not in the selection list, then the encoder must be manually
configured using the Expert list:
p0400[1] = 9999 (user-defined)
p0404[1] = (bit field)
⇒
Click on Continue >
[5] DRIVE-CLiQ encoder: Pulse encoder via Sensor Module Cabinet SMC30
The pulse encoder is connected via the Sensor Module Cabinet SMC30.
⇒
Select encoder 2 to activate the evaluation of the encoder via the Sensor Module Cabinet
SMC30.
⇒
To select a predefined encoder configuration click on the radio button Select standard
encoder from list, and select one of the encoders that is listed.
The following resolvers can be evaluated via the Sensor Module Cabinet SMC30:
●
[3001] 1024 HTL A/B R
●
[3002] 1024 TTL A/B R
●
[3003] 2048 HTL A/B R
●
[3005] 1024 HTL A/B
●
[3006] 1024 TTL A/B
●
[3007] 2048 HTL A/B
●
[3008] 2048 TTL A/B
●
[3009] 1024 HTL A/B unipolar
●
[3011] 2048 HTL A/B unipolar
●
[3020] 2048 TTL A/B R, with sense
●
[3081] SSI, singleturn, 24 V
●
[3082] SSI, multiturn 4096, 24 V
●
[3088] 1024, HTL, A/B, SSI, singleturn
●
[3090] 4096, HTL, A/B, SSI, singleturn
⇒
To enter special encoder configurations, click the Enter data radio button and then the
Encoder data button. The following input screen is displayed for you to enter the required
data.