Table 4- 7
Technical data for 3-ph. 400 V AC, 60 to 210 A, 2Q devices
Article number 6RA80 ..
..25-6DS22-...
..28-6DS22-...
..31-6DS22-...
..75-6DS22-...
Rated DC current
A
60
90
125
210
Rated armature input current
2)
A
49.8
74.7
104
174
Rated power
kW
29.1
43.7
60.6
102
Power loss at
rated DC current (approx.)
W
250
356
409
689
Rated field supply voltage
1)
V
2-ph. 400 V AC (+15% / -20%)
Rated field DC voltage
1)
V
325
325
325
325
Rated field DC current
A
10
10
10
15
Type of cooling
Self-ventilated
Self-ventilated
Self-ventilated
Forced
ventilation
Rated fan supply voltage
V
-
-
-
Fan with internal
power supply
Fan air flow
m
3
/h
-
-
-
300
Fan noise level
dB(A)
-
-
-
70.3
Dimensions (WxHxD)
mm
268x385x252
268x385x252
268x385x252
268x385x252
Weight (approx.)
kg
11
14
14
14
Rated DC voltage for single-phase
operation
V
320
320
320
-
Rated DC current for
single-phase operation
A
42.0
63.0
87.5
-
Содержание SINAMICS Series